HOT AND COLD CHAMBER
Technical Features
Technical Features:
- Robust double walled construction
- Outer body made up of Mild Steel with epoxy Powder Coated finish for long lasting.
- Inner chamber made of rust free Stainless Steel Sheet (304 Grade).
- Outer front double walled door is insulated and is fitted with magnetic gasket for air tight closing & for no temperature loss, provided with lock and key arrangement.
- Temperature Range: -70°C to 100°C
- High-Precision Control: ±0.5K in time, ±1.0K in space
- Cooling Rate: ≥ 5ºC/min
- Heating Rate: ≥ 6ºC/min
- Heat Compensation: 1600W
- Condensing Units CFC free & R-134a eco-friendly refrigerant.
- Test Space Dimensions: 610 x 550 x 350 mm
- External Dimensions: 1700 x 900 x 1300 mm
- Construction Material: High-grade polished stainless steel V2A, Grade 1.4301
- Dehumidification System: Compressed air inlet with air dryer
- Control Panel: 7″ Multi-Touch Display with internal memory, PC connectivity (USB, RS-232, Bluetooth)
- Fault Diagnosis System: Integrated for maintenance support
- High Precision Sensors for accurate reading of temperature.
- Alarms for High and Low temperature and RH set by user
- Door & Viewing Window: Lockable left-hinged door with anti-condensation multi-pane glass (230mm x 230mm)
- Port Holes: Two (125mm diameter each) with removable silicone plugs
- Air Circulation: Internal with heaters & cooling coils outside working space.
- Low & high temperature cut-off settable thermostats & high humidity cut off devices for ensuring safety in case of any failures.
- Refrigeration System: Cascade-type, air-cooled, eco-friendly refrigerant
- High grade PUF Insulation between outer and inner chamber for minimal thermal losses.
- Mobility: Four heavy-duty lockable castor wheels
- Noise Level: ≤ 65 dB(A) at 1 meter
- Weight: 470 Kg (Max.)
- Power Supply: 3/N/PE AC 440V ±10%, 50Hz or Single Phase 230V ±10%, 50Hz, 6.6KW
- If there is a difference of 5 – 8 deg C from any set value, then temperature recovery time up to set value is 20-40 min.
- If there is a difference of 5 – 10% RH from any set value, then Humidity recovery time up to set value is 20-40 min.
Temperature accuracy will be stable in 15-20 minutes after reaching the set value.
Shelves & Loading Capacity
- Shelves: Two stainless steel removable shelves with adjustable height
- Load Capacity: 20kg per shelf, 30kg on floor, total chamber loading of 100kg (minimum)
- Connectivity: Ethernet, USB, RS232
Features:
- Graphical representation of temperature-time
- Digital display of set & actual values
- Fault diagnosis system
- Storage for 50+ programs
- Networking facility (optional)
ADDITIONAL FEATURES
- Graphical Representation of Temperature-Time Data with storage and print facility
- Storage for 99 or more programs
- PC Connectivity & Remote Monitoring
- Adjustable Temperature Limiters for test specimen protection
- Internal Light with External Control
- Networking Capability for system integration